Sr.no | Name of Items | Click Here for Technical specification |
1 | AAAC Conductors | AAAC conductors |
100mm2 Dog | ||
55mm2 Rabbit | ||
34mm2 Weasel | ||
2 | 11KV Distribution Transformers - CRGO & Amorphous | |
5 KVA CRGO/Amorphous, Level-1 / Level-2 | ||
10 KVA CRGO/Amorphous, Level-1 / Level-2 | ||
16 KVA CRGO/Amorphous, Level-1 / Level-2 | Transformer Level 1 & 2 | |
25 KVA CRGO/Amorphous, Level-1 / Level-2 | Corrigendum | |
63 KVA CRGO/Amorphous, Level-1 / Level-2 | ||
100 KVA CRGO/Amorphous, Level-1 / Level-2 | ||
200 KVA CRGO/Amorphous, Level-1 / Level-2 | ||
500 KVA CRGO/Amorphous, Level-1 / Level-2 | ||
3 | LT Distribution Boxes(25 KVA, 63KVA, 100KVA, 200KVA) | LTDB |
4 | 11 KV DO Fuse (Porcelain) | Porcelain DO fuse |
5 | 11 KV DO Fuse (Polymeric) | Plolymeric DO fuse |
6 | 11 KV AB Switch (Porcelain) | Porcelain AB Switch |
7 | 11 KV AB Switch (Polymeric) | Polymeric AB Switch |
8 | 11 KV Lighting arrestor (Porcelain) | Lightning Arrestor |
9 | 2 CORE x 2.5 MM Armoured cable | 2Cx2.5 Armoured cable |
10 | 2 CORE x 4 MM2 LT PVC Cable | 2C & 4C LT PVC |
4 CORE x 4 MM2 LT PVC Cable | ||
4 CORE x 6 MM2 LT PVC Cable | ||
11 | 4 CORE x 10MM2 LT PVC Cable | 4C & 10C LT PVC |
4 CORE x 16 MM2 LT PVC Cable | ||
12 | 10 CORE x 2.5 MM2 Armoured Control Cable | Control cable |
13 | 3.5 CORE x 25 MM2 LT PVC Cable | 3.5 Core LT PVC cable |
3.5 CORE x 50 MM2 LT PVC Cable | ||
3.5 CORE x 70 MM2 LT PVC Cable | ||
3.5 CORE x 150 MM2 LT PVC Cable | ||
14 | 3Cx35+16+25 mm2 LT Aerial Bunch Cable | LT AB cable |
3cx50+25+35 mm2 LT Aerial Bunch Cable | ||
1Cx35+16+25 mm2 / 1Cx35+35 mm2 LT Aerial Bunch Cable | ||
2Cx50+25+35 mm2 LT Aerial Bunch Cable | ||
15 | 3Cx35+70 mm2 11 KV Aerial Bunch Cable | 11KV AB cable |
3Cx70+70 mm2 11 KV Aerial Bunch Cable | ||
3Cx95+80 mm2 11 KV Aerial Bunch Cable | ||
16 | 11 KV 3 C x 185mm2 XLPE Cable | XLPE cable |
17 | GI Wire - 8 SWG(4mm) & 10 SWG(3.15 mm) | G I Wire |
18 | GI Stay Wire - 7/12 SWG (2.5mm) | G I Stay wire |
19 | 11 & 22KV Pin Insulators (Porcelain) | Pin Insulator (porcelain) |
20 | 11 KV Disc Insulator(Porcelain) | Disc Insulator (porcelain) |
21 | 11 KV Polymeric Disc Insulator (Polymeric) | Polymeric Disc (polymeric) |
22 | 11 KV Polymeric Pin Insulator with rod | Polymeric Pin (polymeric) |
23 | 11 & 22KV GI Pin | G I Pin |
24 | 11 KV Disc Hardware | Disc hardware |
25 | HT-LT Stay Insulator & LT Shackle Insulators | HT/LT
Stay insulator & LT Shackle Insulator |
26 | Single Ph. Static 5-30 A. Meter | 1P 5-30A static meter |
27 | 3Ph. 4W Meter of 100/5A of 0.5S Class with DLMS Meter | LTCT meters |
28 | 3Ph. 4W Meter of 200/5A of 0.5 Class with DLMS Meter | |
3 Ph. WH. Current 10/60 Meter | 3P 10-60 Meter | |
29 | 3Ph. LT ERS Meters | LT ERS meter |
30 | 1Ph. LT ERS Meters | |
3 Ph. HT ERS Meters of 0.1 Class | HT ERS meter | |
31 | HT Static TVM -/5 Amp Meter | HT TVM |
32 | HT Static TVM -/1 Amp Meter | |
C.I. Earthing Plate | Earthing plate | |
33 | Ring type CT 100/5 & 200/5 Amp | Ring type CT |
34 | Plastic Seal | Plastic seal |
35 | White color H.D. Rigid PVC Pipe for Earthing/ Earth Terminal | PVC pipe |
36 | EHV Grade Transformer Oil | Transformer oil |
37 | 3 PHASE SMC Meter Box (FOR W/C METER) | 3 Ph SMC Meter Box |
38 | 3 PHASE SMC Meter Box (FOR CT OPERATED METER) | 3 PH SMC CT operated Meter Box |
39 | 1 PHASE SMC Meter Box | 1 Ph SMC Meter Box |
40 | FRP 'V' Cross Arm | V cross arm |
41 | 3 Phase SMC (For HT AMR Meter) SMC Meter Box | 3 Ph HT AMR Meter Box |
42 | SMC Fuse box with 3 nos. of 200A Kit-Kat Fuse | SMC fuse box |
43 | Pole Mounted 1 Phase SMC Junction Box | Junction box |
44 | 100 & 200Amp Kit-Kat Fuse | Kit kat fuse |
45 | GI Earthing Bolt & Nuts | Earthing bolt |
46 | GI Bolt & Nut for LT Shackle Insulator | G I Bolt for LT Shackle insulator |
47 | M.S. Angle 50x50x6mm | M S Angle |
48 | M.S. Angle 65x65x6mm | |
M.S.FLAT 50x6mm | Flat, Roundbar, Channel | |
49 | M.S. Round bar 16mm | |
M.S. Channel 100x50x5 | ||
R.S. Joist 100x116 (9 Mtr) | M S Beam | |
50 | R.S. Joist 100x116 (11 Mtr) | |
11 KV CTPT (10/5 Amp, 15/5 Amp,20/5 Amp,25/5 Amp,30/5 Amp,40/5 Amp,50/5 Amp,75/5 Amp,100/5 Amp,150/5 Amp, 200/5 Amp,250/5 Amp) | CTPT | |
51 | M S Nut & Bolts | M S Nut & Bolts |
52 | FRP ,Fencing | FRP Fencings |
53 | Technical specification of Digital Earth Resistance Tester | TS_DERT |
54 | 2Cx2.5mm2 unarmoured LT PVC cable [IS:694] | Unarmoured LT PVC cable |
55 | 2Cx4mm2 Armoured LT PVC cable [IS:1554] | Armoured LT PVC cable |
56 | 11KV 3CX240mm2 XLPE Cable | XLPE Cable |
57 | 11KV Polymeric Lightning Arrestor | Polymeric Lightning Arrestor |
58 | Technical specification of SMC box with HRC fuse | SMC box with HRC fuse |
59 | Technical Specification of 3 PH AUTOMATIC TEST BENCH | 3 PH AUTOMATIC TEST BENCH |
60 | Technical specifications and GTP for HD Rigid PVC Pipe_40mm | HD Rigid PVC Pipe_40mm |
61 | GI Earthing Strip_Technical Specifications & Drawing | GI Earthing Strip |